Features:
- High resolution images
- Simple User-friendly operation
- Strong Image storage capacity
- Automatic Self-diagnostic maintenance system
- One Key shutdown control
Parameter:
- Tunnel Size : 1000mm(W)800mm(H)
- Load Weight : 200Kgs
- Conveyor Speed : 0.2-0.23m/s
- Radiation Leakage : 0.54 μG/h
- Penetration : 34mm steel
- X-ray resolution : 38WAG
X-Ray Generator:
- X-ray Beam Direction : From Top
- Beam Divergence : 80°
- Tube Voltage : 80-160Kv
- Electronic Current : 0.2-1.25mA
- Cooling : Sealed oil cooling + 100% Dutycycle
Image Function:
- X-ray Converter Arrangement : Dual Energy L-shaped photodiode array detector
- Inorganic/Organic Stripping : Organic substances display in Orange, Inorganic
- substances display in blue, mixtures display in green
- Maximum Image Resolution : 1024768
- Image Storage : 100,000pcs
- Image Display Color : Black/White & Color
- Grey Level : 65536
- Zone & Zoom : 1-9 image zones, 2、4、8 times zooming
- Other Function : Alarm, Review, Density Enhancement, Negative/positive image, Light/Dark Enhancement, automatic count, One Key Power Off, Working status display, Date & time display, Rush Stop Protection, Dangerous Alarm, System Failure Alarm etc.
Working Environment:
- Work Temperature & Humidity : 0℃~+45℃/ 20%~95%(Non Cooling), -10℃~+45℃/ 5%~95%(Optional)
- Storage Temperature & Humidity : -40℃~70℃/ 5%~95%(Non Cooling)
- Power : 220VAC(+10%~-15%,,50Hz±3Hz)
Packing:
- XJ10080 ( Two separate wooden boxes for 1set xray machine)
- Package size of xray: 2610 (L) 1440 (W) 2060mm(H) Package size of operation plate and computer:1165mm(L)660mm(W)1280mm(H)
- Gross weight:1,000kgs
| |
- Model No : - NTCXLD-100100
- Tunnel size : 1000(w)×1000(h)mm
- Conveyor speed : 0.2 m/s
- Maximum Load Power : 1,500 kg
- Steel penetration : 30mm armor plate
- Channel size : 1000mm (W) × 1000mm (H)
- Ray beam direction : from top-down vertical irradiation
- Operating voltage : 220 VAC (+10% ~ -15%), 50 ± 3HZ
- Power consumption : 1.4KVA
- Conveyor speed : 0.2m / s
- Ray source properties : 140kV, 0.5mA
- Leakage quantity : 5cm away from the chassis at <2mSv / h (0.2mR / h), a
- typical value of <1mSv / h (0.1mR / h)
- Standard leakage dose : in line with GB15208-94 standard of protection.
- Maximum Load Power : 1500Kg
- Spatial resolution : Æ0.10mm wire
- Penetration : 30mm thick steel plate
- Single-ray radiation doses : 1mSv / h
- Film Safety : to ensure safety of high-speed film (ISO 1600)
- Operating temperature : Sealed oil-cooling cycle
- Storage temperature : Equipment to provide a good grounding terminal
- Relative Humidity : 0 ℃ ~ 45 ℃
- Cooling / work cycle : Seal circulating oil cooling / 100%
- X-ray sensor : L-forms of photodiode array
- Can display grayscale : 4096 (12 bit)
- Equipment Grounding: Equipment to provide a good grounding terminal
- Host Noise : 60dB (A)
| |
|
Mr. Amit Maske [ Director ] GF-5, Anukrupa Apartment, Barlingey Leyout Near Yashodha Nagar Bus Stop, Hingana Road Nagpur, Maharashtra, India E-Mail: newtech0282@yahoo.com Telephone: +(91)-9923911811/ 9975864122 Mobile: +(91)-9923911811/ 9975864122
|
|
|